SC Daily Load Shape and Duck Curve by Hour, 14 October to 11 November 2026

In the 29 complete local days from 14 October to 11 November 2026, electricity demand in SC averaged 2,867 MW and typically peaked at 18:00 local time (3,151 MW) and bottomed out at 03:00 (2,499 MW). With solar taken off, the remaining load fell to 2,499 MW at 03:00 and then rose 391 MW between 15:00 to 18:00. Hours are local clock time (America/New_York).

Key Facts

  • Over 29 complete local days from 14 October to 11 November 2026, average demand in SC was 2,867 MW. The hour of the day with the highest average demand was 18:00 local time (3,151 MW) and the lowest was 03:00 (2,499 MW).
  • The largest three hour rise in average demand was 80 MW, between 15:00 to 18:00 local time.
  • The single highest hour of demand in the 30 day window was 4,116 MW, in the hour starting 15 Oct 2026, 16:00 EDT (UTC-04:00).
  • Solar output averaged 382 MW at its 10:00 peak, 13% of average demand.
  • Demand minus solar (net load) averaged 2,740 MW, fell to 2,499 MW at 03:00 and rose 391 MW over the three hours from 15:00 to 18:00, 14% of average demand.

Average Day by Local Hour

29 days to 2026-11-11, America/New_York time
SC average demand and net generation by local hour Average electricity demand in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. It was lowest at 03:00 (2,499 MW) and highest at 18:00 (3,151 MW). Net generation is the power produced inside the grid, so it differs from demand by net imports. 0 1,000 2,000 3,000 4,000 00:0003:0006:0009:0012:0015:0018:0021:00
Average electricity demand in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. It was lowest at 03:00 (2,499 MW) and highest at 18:00 (3,151 MW). Net generation is the power produced inside the grid, so it differs from demand by net imports.
Mean MW by local hour, 2026-10-14 to 2026-11-11
SC average demand and net generation by local hour
Local hour (America/New_York)DemandNet generation
00:002,600 MW1,566 MW
01:002,531 MW1,486 MW
02:002,506 MW1,467 MW
03:002,499 MW1,457 MW
04:002,536 MW1,497 MW
05:002,621 MW1,577 MW
06:002,770 MW1,714 MW
07:002,836 MW1,801 MW
08:002,889 MW1,878 MW
09:002,927 MW1,933 MW
10:002,942 MW1,941 MW
11:002,951 MW1,947 MW
12:002,996 MW1,984 MW
13:003,037 MW2,016 MW
14:003,059 MW2,031 MW
15:003,071 MW2,032 MW
16:003,101 MW2,015 MW
17:003,129 MW1,976 MW
18:003,151 MW1,950 MW
19:003,141 MW1,913 MW
20:003,050 MW1,826 MW
21:002,945 MW1,774 MW
22:002,824 MW1,764 MW
23:002,693 MW1,671 MW
SC duck curve: demand and net load by local hour Average demand and net load (demand minus solar) in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. Net load was lowest at 03:00 (2,499 MW) and then rose 391 MW between 15:00 to 18:00. 0 1,000 2,000 3,000 4,000 00:0003:0006:0009:0012:0015:0018:0021:00
Average demand and net load (demand minus solar) in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. Net load was lowest at 03:00 (2,499 MW) and then rose 391 MW between 15:00 to 18:00.
Mean MW by local hour, 2026-10-14 to 2026-11-11
SC duck curve: demand and net load by local hour
Local hour (America/New_York)DemandNet load (demand minus solar)
00:002,600 MW2,600 MW
01:002,531 MW2,531 MW
02:002,506 MW2,506 MW
03:002,499 MW2,499 MW
04:002,536 MW2,536 MW
05:002,621 MW2,621 MW
06:002,770 MW2,769 MW
07:002,836 MW2,805 MW
08:002,889 MW2,711 MW
09:002,927 MW2,586 MW
10:002,942 MW2,561 MW
11:002,951 MW2,571 MW
12:002,996 MW2,626 MW
13:003,037 MW2,674 MW
14:003,059 MW2,716 MW
15:003,071 MW2,752 MW
16:003,101 MW2,860 MW
17:003,129 MW3,030 MW
18:003,151 MW3,144 MW
19:003,141 MW3,141 MW
20:003,050 MW3,050 MW
21:002,945 MW2,945 MW
22:002,824 MW2,824 MW
23:002,693 MW2,693 MW
SC average solar output by local hour Average solar generation in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. Solar peaked at 10:00 at 382 MW. 0 100 200 300 400 00:0003:0006:0009:0012:0015:0018:0021:00
Average solar generation in SC by local clock hour over 29 complete local days from 14 October to 11 November 2026. Solar peaked at 10:00 at 382 MW.
Mean MW by local hour, 2026-10-14 to 2026-11-11
SC average solar output by local hour
Local hour (America/New_York)Solar
00:000 MW
01:000 MW
02:000 MW
03:000 MW
04:000 MW
05:000 MW
06:001 MW
07:0031 MW
08:00178 MW
09:00341 MW
10:00382 MW
11:00380 MW
12:00370 MW
13:00363 MW
14:00344 MW
15:00319 MW
16:00240 MW
17:0099 MW
18:007 MW
19:000 MW
20:000 MW
21:000 MW
22:000 MW
23:000 MW
Average SC demand, net generation, solar and net load by local hour
Local hourDemandNet generationSolarNet load
00:00 2,600 MW 1,566 MW 0 MW 2,600 MW
01:00 2,531 MW 1,486 MW 0 MW 2,531 MW
02:00 2,506 MW 1,467 MW 0 MW 2,506 MW
03:00 2,499 MW 1,457 MW 0 MW 2,499 MW
04:00 2,536 MW 1,497 MW 0 MW 2,536 MW
05:00 2,621 MW 1,577 MW 0 MW 2,621 MW
06:00 2,770 MW 1,714 MW 1 MW 2,769 MW
07:00 2,836 MW 1,801 MW 31 MW 2,805 MW
08:00 2,889 MW 1,878 MW 178 MW 2,711 MW
09:00 2,927 MW 1,933 MW 341 MW 2,586 MW
10:00 2,942 MW 1,941 MW 382 MW 2,561 MW
11:00 2,951 MW 1,947 MW 380 MW 2,571 MW
12:00 2,996 MW 1,984 MW 370 MW 2,626 MW
13:00 3,037 MW 2,016 MW 363 MW 2,674 MW
14:00 3,059 MW 2,031 MW 344 MW 2,716 MW
15:00 3,071 MW 2,032 MW 319 MW 2,752 MW
16:00 3,101 MW 2,015 MW 240 MW 2,860 MW
17:00 3,129 MW 1,976 MW 99 MW 3,030 MW
18:00 3,151 MW 1,950 MW 7 MW 3,144 MW
19:00 3,141 MW 1,913 MW 0 MW 3,141 MW
20:00 3,050 MW 1,826 MW 0 MW 3,050 MW
21:00 2,945 MW 1,774 MW 0 MW 2,945 MW
22:00 2,824 MW 1,764 MW 0 MW 2,824 MW
23:00 2,693 MW 1,671 MW 0 MW 2,693 MW

Each value is the mean over 29 complete local days from 14 October to 11 November 2026, weekdays and weekends together, for the hour starting at that local clock time. Net load is demand minus solar generation. The single highest hour of demand in the whole 30 day window was 4,116 MW; it is a published reading, not an average, and is not part of the profile above.

Source: U.S. Energy Information Administration (EIA). (US Government work, public domain) Data as of 2026-11-11. Profiles are computed by World Power Monitor from the operator's hourly series.

Assumptions

  • Hours are local clock time in America/New_York. A local day is used only if it is whole inside the 30 day window and at least 22 of its hours are complete; the profile uses the 29 most recent such days. Daylight saving follows the local clock: on a clock change day the missing hour is absent and the repeated hour is averaged over both readings.
  • The average mixes weekdays and weekends and covers only 29 days, so it describes recent conditions, not a seasonal norm.
  • The evening ramp is the largest rise over three hours in the average profile, starting between 14:00 and 20:00 local time.
Cite this page
APA 7

World Power Monitor. (2026). SC Daily Load Shape and Duck Curve by Hour. https://worldpowermonitor.com/load-shapes/sc/

Plain text

World Power Monitor. SC Daily Load Shape and Duck Curve by Hour. Data as of 2026-11-11. Data from U.S. Energy Information Administration. https://worldpowermonitor.com/load-shapes/sc/

BibTeX
@misc{wpm_load_shapes_sc_2026,
  title = {{SC Daily Load Shape and Duck Curve by Hour}},
  author = {{World Power Monitor}},
  year = {2026},
  note = {Data as of 2026-11-11. Data from U.S. Energy Information Administration.},
  url = {https://worldpowermonitor.com/load-shapes/sc/}
}

Permalink: https://worldpowermonitor.com/load-shapes/sc/

The Copy buttons add today's date as the access date.